152 research outputs found

    Pharmacokinetic and pharmacodynamic analysis in anesthesia : a modeling odyssey

    Get PDF
    <span style="font-size:12.0pt;font-family:"Times New Roman","serif"; mso-fareast-font-family:Calibri;mso-fareast-theme-font:minor-latin;mso-ansi-language: NL;mso-fareast-language:NL;mso-bidi-language:AR-SA">This thesis concerns five studies where the statistical consequences of violations of modeling assumptions are assessed using experimental and simulated pharmacokinetic-pharmacodynamic data. The first study describes the development of an open source web application for Bland-Altman analysis of comparison data, which is able to take into account both intra- and interindividual variability. In the second study the behavior of Akaike's information theoretic criterion is investigated in the presence of interindividual variability. The effects of neglecting or allowing for process noise are described in the third and fourth studies, for surrogate measures of clinical endpoints such depth of anesthesia and analgesia. In the fifth study pharmacodynamic model parameter estimates are compared when these are based on venous versus arterial blood samples.LUMC / Geneeskunde Repositoriu

    Entropies of the EEG: The effects of general anaesthesia

    Get PDF
    The aim of this paper was to compare the performance of different entropy estimators when applied to EEG data taken from patients during routine induction of general anesthesia. The question then arose as to how and why different EEG patterns could affect the different estimators. Therefore we also compared how the different entropy estimators responded to artificially generated signals with predetermined, known, characteristics. This was done by applying the entropy algorithms to pseudoEEG data: (1) computer-generated using a second-order autoregressive (AR2) model, (2) computer-generated white noise added to step signals simulating blink and eyemovement artifacts and, (3) seeing the effect of exogenous (computer-generated) sine-wave oscillations added to the actual clinically-derived EEG data set from patients undergoing induction of anesthesia

    Esketamine counters opioid-induced respiratory depression

    Get PDF
    Perioperative Medicine: Efficacy, Safety and Outcom

    Stereoselective ketamine effect on cardiac output: a population pharmacokinetic/pharmacodynamic modelling study in healthy volunteers

    Get PDF
    Background: Ketamine has cardiac excitatory side-effects. Currently, data on the effects of ketamine and metabolite concentrations on cardiac output are scarce. We therefore developed a pharmacodynamic model derived from data from a randomised clinical trial. The current study is part of a larger clinical study evaluating the potential mitigating effect of sodium nitroprusside on the psychedelic effects of ketamine.Methods: Twenty healthy male subjects received escalating esketamine and racemic ketamine doses in combination with either placebo or sodium nitroprusside on four visits: (i) esketamine and placebo, (ii) esketamine and sodium nitroprusside, (iii) racemic ketamine and placebo, and (iv) racemic ketamine and sodium nitroprusside. During each visit, arterial blood samples were obtained and cardiac output was measured. Nonlinear mixed-effect modelling was used to analyse the cardiac output time-series data. Ketamine metabolites were added to the model in a sequential manner to evaluate the effects of metabolites.Results: A model including an S-ketamine and S-norketamine effect best described the data. Ketamine increased cardiac output, whereas modelling revealed that S-norketamine decreased cardiac output. No significant effects were detected for R-ketamine, metabolites other than S-norketamine, or sodium nitroprusside on cardiac output.Conclusions: S-Ketamine, but not R-ketamine, increased cardiac output in a dose-dependent manner. In contrast to Sketamine, its metabolite S-norketamine reduced cardiac excitation in a dose-dependent manner.Perioperative Medicine: Efficacy, Safety and Outcome (Anesthesiology/Intensive Care

    Flushing of an intravenous catheter: a cause for unreliable laboratory results

    Get PDF
    Introduction: Phlebotomy is an error-prone process in which mistakes are difficult to reveal. This case report describes the effect on laboratory results originating from a blood sample collected in close proximity to an intravenous catheter. Materials and methods: A 69-year-old male patient was referred to the Emergency department where pneumonia was suspected. Phlebotomy was performed to collect blood samples to assess electrolytes, renal function, liver function, infection and haematological parameters. Results: The laboratory analysis showed reduced potassium and calcium concentrations. To prevent life-threatening cardiac failure the clinician decided to correct those electrolytes. Remarkably, the electrocardiogram showed no abnormalities corresponding to hypokalaemia and hypocalcaemia. This observation, in combination with an overall increase in laboratory parameters with the exception of sodium and chloride, led to the suspicion of a preanalytical error. Retrospectively, an intravenous catheter was inserted in close proximity of the puncture place but no continuous infusion was started prior to phlebotomy. However, the intravenous catheter was flushed with sodium chloride. Since potential other causes were excluded, the flushing of the intravenous catheter with sodium chloride prior to phlebotomy was the most probable cause for the deviating laboratory results and subsequently for the unnecessary potassium and calcium suppletion. Conclusion: This case underlines the importance of caution in the interpretation of laboratory results obtained from specimens that are collected in the proximity of an intravenous catheter, even in the absence of continuous infusion

    Predictors and outcome impact of perioperative serum sodium changes in a high-risk population.

    Get PDF
    BACKGROUND: The perioperative period may be associated with a marked neurohumoral stress response, significant fluid losses, and varied fluid replacement regimes. Acute changes in serum sodium concentration are therefore common, but predictors and outcomes of these changes have not been investigated in a large surgical population. METHODS: We carried out a retrospective cohort analysis of 27 068 in-patient non-cardiac surgical procedures in a tertiary teaching hospital setting. Data on preoperative conditions, perioperative events, hospital length of stay, and mortality were collected, along with preoperative and postoperative serum sodium measurements up to 7 days after surgery. Logistic regression was used to investigate the association between sodium changes and mortality, and to identify clinical characteristics associated with a deviation from baseline sodium >5 mmol litre(-1). RESULTS: Changes in sodium concentration >5 mmol litre(-1) were associated with increased mortality risk (adjusted odds ratio 1.49 for a decrease, 3.02 for an increase). Factors independently associated with a perioperative decrease in serum sodium concentration >5 mmol litre(-1) included age >60, diabetes mellitus, and the use of patient-controlled opioid analgesia. Factors associated with a similar increase were preoperative oxygen dependency, mechanical ventilation, central nervous system depression, non-elective surgery, and major operative haemorrhage. CONCLUSIONS: Maximum deviation from preoperative serum sodium value is associated with increased hospital mortality in patients undergoing in-patient non-cardiac surgery. Specific preoperative and perioperative factors are associated with significant serum sodium changes.This work was supported by the Cambridge University Division of Anaesthesia.This is the author accepted manuscript. The final version is available from Oxford University Press via http://dx.doi.org/10.1093/bja/aeu40

    Ketamine Pharmacokinetics: A Systematic Review of the Literature, Meta-analysis, and Population Analysis

    Get PDF
    Background: Several models describing the pharmacokinetics of ketamine are published with differences in model structure and complexity. A systematic review of the literature was performed, as well as a meta-analysis of pharmacokinetic data and construction of a pharmacokinetic model from raw data sets to qualitatively and quantitatively evaluate existing ketamine pharmacokinetic models and construct a general ketamine pharmacokinetic model.Methods: Extracted pharmacokinetic parameters from the literature (volume of distribution and clearance) were standardized to allow comparison among studies. A meta-analysis was performed on studies that performed a mixed-effect analysis to calculate weighted mean parameter values and a meta-regression analysis to determine the influence of covariates on parameter values. A pharmacokinetic population model derived from a subset of raw data sets was constructed and compared with the meta-analytical analysis.Results: The meta-analysis was performed on 18 studies (11 conducted in healthy adults, 3 in adult patients, and 5 in pediatric patients). Weighted mean volume of distribution was 252 l/70 kg (95% CI, 200 to 304 l/70 kg). Weighted mean clearance was 79 l/h (at 70 kg; 95% CI, 69 to 90 l/h at 70 kg). No effect of covariates was observed; simulations showed that models based on venous sampling showed substantially higher context-sensitive half-times than those based on arterial sampling. The pharmacokinetic model created from 14 raw data sets consisted of one central arterial compartment with two peripheral compartments linked to two venous delay compartments. Simulations showed that the output of the raw data pharmacokinetic analysis and the meta-analysis were comparable.Conclusions: A meta-analytical analysis of ketamine pharmacokinetics was successfully completed despite large heterogeneity in study characteristics. Differences in output of the meta-analytical approach and a combined analysis of 14 raw data sets were small, indicative that the meta-analytical approach gives a clinically applicable approximation of ketamine population parameter estimates and may be used when no raw data sets are available.</p

    Deep neuromuscular block does not improve surgical conditions in patients receiving sevoflurane anaesthesia for laparoscopic renal surgery

    Get PDF
    Background: Deep neuromuscular block is associated with improved working conditions during laparoscopic surgery when propofol is used as a general anaesthetic. However, whether deep neuromuscular block yields similar beneficial effects when anaesthesia is maintained using volatile inhalation anaesthesia has not been systematically investigated. Volatile anaesthetics, as opposed to intravenous agents, potentiate muscle relaxation, which potentially reduces the need for deep neuromuscular block to obtain optimal surgical conditions. We examined whether deep neuromuscular block improves surgical conditions over moderate neuromuscular block during sevoflurane anaesthesia.Methods: In this single-centre, prospective, randomised, double-blind study, 98 patients scheduled for elective renal surgery were randomised to receive deep (post-tetanic count 1-2 twitches) or a moderate neuromuscular block (train-of-four 1-2 twitches). Anaesthesia was maintained with sevoflurane and titrated to bispectral index values between 40 and 50. Pneumoperitoneum pressure was maintained at 12 mm Hg. The primary outcome was the difference in surgical conditions, scored at 15 min intervals by one of eight blinded surgeons using a 5-point Leiden-Surgical Rating Scale (L-SRS) that scores the quality of the surgical field from extremely poor(1) to optimal(5).Results: Deep neuromuscular block did not improve surgical conditions compared with moderate neuromuscular block: mean (standard deviation) L-SRS 4.8 (0.3) vs 4.8 (0.4), respectively (P=0.94). Secondary outcomes, including unplanned postoperative readmissions and prolonged hospital admission, were not significantly different.Conclusions: During sevoflurane anaesthesia, deep neuromuscular block did not improve surgical conditions over moderate neuromuscular block in normal-pressure laparoscopic renal surgery.Transplant surger

    Does nociception monitor-guided anesthesia affect opioid consumption? a systematic review of randomized controlled trials

    Get PDF
    Monitors that estimate nociception during anesthesia may be used to guide opioid and other analgesics administration to optimize anesthesia care and possibly outcome. We reviewed the literature to evaluate current evidence of the effect of nociception-guided management over standard anesthesia practice during surgery. A systematic review of the literature on the effect of nociception monitoring on anesthesia practice was conducted. Reports were eligible if they compared nociception-guided anesthesia to standard practice during surgery. Primary endpoint of this review is intraoperative opioid consumption. Secondary endpoints included hemodynamic control, postoperative pain and pain treatment. We identified 12 randomized controlled trials that compared one of five different nociception monitoring techniques to standard anesthesia care. Most studies were single center studies of small sample size. Six studies reported intraoperative opioid consumption as primary outcome. There was considerable variability with respect to surgical procedure and anesthesia technique. For nociception monitors that were investigated by more than one study, analysis of the pooled data was performed. The surgical plethysmographic index was the only monitor for which an intra operative opioid sparing effect was found. For the other monitors, either no effect was detected, or pooled analysis could not be performed due to paucity of study data. On secondary outcomes, no consistent effect of nociception-guided anesthesia could be established. Although some nociception monitors show promising results, no definitive conclusions regarding the effect of nociception monitoring on intraoperative opioid consumption or other anesthesia related outcome can be drawn. Clinical trial numberPROSPERO ID 102913.Perioperative Medicine: Efficacy, Safety and Outcome (Anesthesiology/Intensive Care
    corecore